6. Temporarily set the Weight in place against the Retainers with 4 screws. (Do not 
tighten.)
Figure 4-101.  Attach the Weight
7. Insert 1.60mm thickness gauges between the left and right sides of the Weight and 
the Head and leave them in place.
Figure 4-102.  Insert thickness gauges
C A U T I O N
Apply screw locking glue to the tips of M3x14 screws.
CP M3X14
W Sems M3X8
Insert 1.60mm thickness gauges