EPSON Stylus Pro 10000/10000CF/10600 Revision D
Product Description Maintenance Mode 2 50
Initialize ink capacity
Selecting this mode allows the user to initialize the ink capacity counter.
Initialize FL BOX
Selecting this mode allows the user to initialize the FL BOX capacity counter (Protect
counter D)
Provided that value of protect counter D will be added to Protect counter A before
initialization.
Initialize waste ink capacity
Selecting this mode allows the user to initialize the waste ink capacity counter (Protect
counter A).
CSIC detection level
Selecting this mode allows the user to adjust CSIC detection level. Each adjustment
value indicates as following;
ED MODE=X: It acquires information from CSIC and informs user of it.
ED MODE=N: It detects Japanese/overseas cartridge and doesn’t inform users of it.
ED MODE=O: It acquires information from CSIC and doesn’t inform user of it at all.
Failed nozzle limit (Dye/Pigment)
In case of nozzle check error with auto nozzle check, nozzle check error doesn’t occur
until it meet following condition permitting optional number of nozzle clogging.
This setting applies to all of nozzle check (operating or before printing)
(While it prints 200million shots per nozzle with Y head.)
Ink cartridge type
It sets printer model (dye/pigment) compulsorily to distinguish ink cartridge.
This function is used to return print model to "neutral".
Each value indicates as followings;
NPD = 0: Neutral
NPD = 1: Pigment model
NPD = 2: Dye type model
Selectable M/W 1, 2
Set the most suitable value of irregular M/W for each printer, and banding will
decrease.
There are 8 types for 720x720dpi FOL and 5 types for 1440x720dpi 4 pass.
MW7 balance
Adjust MW7 feeding in mode C when printing.
MW feeding per pass is defined as following;
N pass --- 1/720inch + d x unit
N+1pass --- 349/720inch -d x unit
Table 1-51. Maintenance mode 2 setup items
Item Panel display Setup value
Bi-D offset setting #1
(VSD1, 240CPS, Small)
BID OFFSET #1 -4~0~+4
Bi-D offset setting #2
(VSD2, 300CPS, Large)
BID OFFSET #2 -4~0~+4
CSIC detection level ED MODE O/N/X
Failed nozzle limit (Dye model) NZLD 0 ~2 ~45
Failed nozzle limit (Pigment model) NZLD 0 ~2 ~45
Ink cartridge type NPD 0,1,2
Selectable M/W (720x720 FOL) MW1 SELECT 1, 2, 3, 4, 5, 6, 7
Selectable M/W (1440x720 FOL) MW2 SELECT 1, 2, 3, 4
M/W7 balance adjustment MW7 BALANCE -30 ~ 0
~ +30
FL BOX life display FLBL DET ON, OFF