2. Replacement and adjustment of parts
27670
2/2
27670
Tablet replenishment section
IMPORTANT
• Stopping the elevator at the elevator middle sensor position
1. Select Tablet Replenishment Section 1 on the Output Check.
2. When Elevator Motor (Up) is selected and Execute is clicked, the elevator lifts up and stops for 2 seconds at the
position where the elevator middle sensor is closed.
3. When two seconds passes, starts again. When detected by the elevator upper sensor, stops.
5. Reassemble the parts.
6. Check if the tablet falls from the elevator via Output Check.
☞35320