4. Troubleshooting
40900
12/13
40900
Attention message: F replenishment
No. 00916[F]
PSR is empty.
Countermeasure message
Add 20 liters PSR to the PSR replenishment tank.
Attention message release
YES
NOTE
When the above attention message appears, printing process stops.
Condition
NOTE
Attention message No. 00916 is not shown while the automatic Daily Setup is performed.
Check Point
Diagnosis
NOTE
To access the wiring diagrams, click Wiring diagrams in Bookmarks.
You can select from two methods to make solution from PSR tablets. Although the ratio of water to tablets is slightly different
between these methods, it does not affect solution quality.
1. Dissolve five tablets in 20 liters of water, then replenish this solution into the replenishment tank.
2. Dissolve five tablets in 25 liters of water, then replenish 20 liters of this solution into the replenishment tank.
Suffix number Condition
00000 PSR (Lower) Replenishment Solution Level Sensor turns off.
The power supply is turned on when PSR (Lower) Replenishment Solution Level Sensor is off.
Add PSR. -
Check the PSR (Lower) Replenishment Solution Level Sensor status via Input Check.
35220
Failed part Manual No.
PSR (Lower) Replenishment Solution Level Sensor 63280
F replenishment I/O PCB
66800
Processor control PCB 66200
Distributed by: minilablaser.com