RX2530 M4 Upgrade and Maintenance Manual 407
System board and components
Ê Install all riser modules, see section "Expansion cards and riser cards" on
page 219.
Ê Install all PSUs, see section "Installing a hot-plug PSU" on page 114.
Ê Only for system with air cooling: install the air duct, see section "Installing
the air duct" on page 74.
Ê "Reassembling" on page 57
Ê "Connecting the power cord" on page 63
Ê "Verifying the system time settings" on page 94
Ê Connect all external cables.
Ê "Updating expansion card firmware" on page 85
I When updating to BIOS 1.15.0 or higher with Red Hat Enterprise
Linux 7 as operating system, a network name for onboard LAN, as
well as for the OCP connectors may change.
Ê If applicable, activate TPM functionality in the system BIOS under Security
> TPM (Security Chip) Setting > Security Chip. For more information, see
the corresponding BIOS Setup Utility reference manual.
Ê "Verifying system information backup/restore" on page 84
Ê "Looking for MAC/WWN/GUID and SAS addresses" on page 100
Ê "Updating the NIC configuration file in a Linux and VMware environment" on
page 97
Ê "Switching on the server" on page 66
I When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the
message CPU has been changed.
This only indicates that the CPU configuration has been altered.
There is no technical problem.
Proceed as follows:
Ê Restart your server.
Ê As soon as the startup screen appears, press the [F2] function
key to enter the BIOS.
If a password is assigned, enter the password and press [Enter].