428 Upgrade and Maintenance Manual RX2530 M4
Appendix A
17.2.3.2 Indicators on the I/O panel
ID, CSS and Global Error indicators
Figure 320: ID, CSS and Global Error indicators
Pos. Indicator Status Description
1
ID indicator,
see also
"iRMC-
related
status
signals" on
page 429
blue on
The server has been highlighted using
ServerView Operations Manager, iRMC web
interface or the ID button on the front panel for
easy identification.
flashing
blue
The server has been highlighted for easy
identification using the iRMC (AVR) with
disabled local VGA output.
2
Global Error
indicator,
see also
"iRMC-
related
status
signals" on
page 429
off
No critical event detected (non CSS
component).
orange
on
Prefailure event detected (non CSS
component).
flashing
orange
Non CSS component failure detected.
Possible causes:
System is out of the specified range
Defective sensor
CPU error
Error detected by server management
software

Table of Contents