LCD Display D1 Servo Drive User Manual
7-12 HIWIN MIKROSYSTEM CORP.
Step 1: Press Enter key to go to the editing mode of LCD No. 065 (The dynamic cursor is on the left of
the second line.)
Step 2: Press Down key once to move the blinking cursor to the position of 0.
Step 3: Press F key once (The function of Up key and Down key is to change parameter value.).
Step 4: Press Up key twice to let the number become 1. For the switching sequence of numbers,
please refer to figure 7.4.2.2.
Step 5: Press F key once (The function of Up key and Down key changes to moving cursor.).
Step 6: Press Down key twice to let the blinking cursor move to the position of 5.
Step 7: Press F key once (The function of Up key and Down key changes to changing parameter
value.).
Step 8: Press Down key for four times to let the number become 2.
Step 9: Press Enter key and CG has been changed to 1.2.
Note:
While using parameter editing function, please pay attention to the usage of F key.
(1) When F key is pressed for less than one second, the function of Up key and Down key can be changed to
moving cursor or changing parameter value.
(2) When F key is pressed for more than two seconds, the display changes to LEVEL ONE and the changes will
be ignored.