3.7 Address Configuration
A3-77
ME0384-4A
Positioner 2 mode assignment
Assigning the positioner 2 mode is as follows.
PLC output = Axis control signal
Address
*
PLC input = Axis status signal
Address
*
* m is the head register address of each axis. n is the head relative address of each axis.
p is the head module address of each axis.
CC-Link, CC-Link IE Field, and DeviceNet have word addresses, PROFIBUS-DP, EtherNet/IP, and
EtherCAT use byte addresses, and PROFINET-IO uses 4-word module addresses.
I/O signal list and alarm content list are all the same except for "Present position data" in
positioner 1 mode. In positioner 1 mode, the "Present position data" is included in the PLC
input signal. It is not included in positioner 2 mode. Refer to pages A3-74 to A3-76.
-
-
-
-
-