3.6 Precautions
B3-14
ME0384-4A
Chapter 3 Absolute Reset
Startup Section
3.6 Precautions
[Precautions when changing parameters]
If the following parameters are changed, an absolute error will occur. After changing the
parameters, absolute reset must be performed once again.
(1) Parameter No.5 "Homing direction"
(2) Parameter No. 22 "Homing offset"
(3) Parameter No. 77 "Ball screw lead length"
(4) Parameter No. 78 "Axis motion type"
[Absolute Battery handling]
Always observe the following safety precautions.
(1) Do not disassemble under any circumstances. The electrolyte is a strong alkali solution. It is
harmful to skin and clothing.
(2) Never short the electrodes out (never directly connect + and - electrodes). Devices may be
damaged, or the generated heat may cause burns.
(3) Never place into fire, as it may burst.
Also do not submerge underwater, as the battery will cease to function.
(4) Do not solder directly.
The safety mechanism may explode due to damage to the safety valve in the battery cap.
(5) If the power remains shut OFF for an extended period of time with the connector connected,
deep discharge will take place, leakage may occur and the performance/life of the battery
may be significantly lowered.
Unplug the connector when shutting OFF the power for extended periods of time due to
equipment relocation, remodeling, etc.
(6) When disposing, take measures such as the use of an appropriate collection box installed at
a recycling center.