7.2 How to Read the Model Number
A7-3
ME0384-4A
Specifications Section
Chapter 7 Simple Absolute Unit
7.2 How to Read the Model Number
The simple absolute unit models are as follows.
1 simple absolute unit is required for each actuator axis.
Also, the applicable driver units should be the 24 pulse motor type (RCON-PC) and the 24V AC
servo-motor type (RCON-AC) only.
A cable (model: CB-ADPC-MPA005, length 50 cm) is included for connection to the driver unit.
Cables of lengths other than 50 cm must be prepared separately as needed. The cable length
should be selected based on the driver unit and simple absolute unit installation positions.
Simple absolute unit model
RCON ABU
Motor type
P
Stepper motor
type
A
AC servo motor
type
Simple Absolute Unit
for AC servo motor
(Model: RCON-ABU-A)
Simple Absolute Unit
for stepper motor
(Model: RCON-ABU-P)