2.3 Specifications
A2-7
ME0384-4A
Specifications Section
Chapter 2 System Configuration and Specifications
2.3 Specifications
General specifications
The specifications regarding installation conditions are listed below.
Item Specifications
Ambient operating
temperature
0~55°C (with temperature derating) (0~40°C for simple absolute units)
Refer to "Operating temperature range (page A2-20)" for details
Ambient operating
humidity
85% RH or less, non-condensing
Ambient storage
temperature
-20~70 (0~40°C for simple absolute units)
Operating
atmosphere
Avoid corrosive gas and in particular avoid excessive dust
Altitude 1,000m
Vibration
resistance
Frequency: 10~57 Hz/Amplitude: 0.075mm, Frequency: 57~150 Hz/
Acceleration: 9.8m/s
2
XYZ directions Sweep time: 10 minutes Number of sweeps: 10 times
Shock resistance Drop height: 800mm 1 corner, 3 edges, 6 faces
Overvoltage
category
I
Electric shock
protection
mechanism
24V System : Class III
200V System : Class I
Pollution degree II
Degree of
protection
IP20
Insulation
withstanding
voltage
500VDC 10MΩ
Generated heat
(per unit)
RCON-PC
PowerCON: No 5.0W
PowerCON: Yes 8.0W
RCON-PCF PowerCON: No 19.2W
RCON-AC
Standard / High accel/decel /
Energy saving
4.5W
RCON-DC Standard 3.0W
RCON-SC Standard 54W
RCON-PS2 - 42W
Cooling method Natural air cooling and forced air cooling by fan unit