97
Learning Basic Features
TI Pulse Input Setting Details
Code
Description
IN-01 Freq at
100%
Configures the frequency reference at the maximum pulse input. The
frequency reference is based on 100% of the value set with IN-96.
If IN-01 is set to 40.00 and codes IN-9396 are set at default, 32
kHz input to TI yields a frequency reference of 40.00 Hz.
If IN-96 is set to 50.00 and codes IN-01, IN-9395 are set at default,
32 kHz input to the TI terminal yields a frequency reference of 30.00
Hz.
IN-91 TI Monitor
Displays the pulse frequency supplied at TI.
IN-92 TI Filter
Sets the time for the pulse input at TI to reach 63% of its nominal
frequency (when the pulse frequency is supplied in multiple steps).
IN-93 TI Pls x1
IN-96 TI Perc y2
Configures the gradient level and offset values for the output frequency.
IN-97 TI Inverting
IN-98 TI
Quantizing
Identical to IN-1617 (refer to IN-16 V1 Inverting/IN-17 V1 Quantizing on
page 88)