Learning Advanced Features
5.45 Multi-function Output On/Off Control
Set reference values (on/off level) for analog input and control output relay or multi-function
output terminal on/off status accordingly.
Group
Code
Name
LCD Display
Parameter
Setting
Setting Range
Unit
ADV
66
Output terminal on/off
control mode
On/Off Ctrl
Src
1
V1
0–8
-
67
Output terminal on
level
On-C Level
90.00
Output terminal off
level–100.00%
%
68
Output terminal off
level
Off-C Level
10.00
0.00–Output terminal
on level
%
OUT
31
Multi-function relay 1
item
Relay 1
26
On/Off
-
-
33
Multi-function output 1
item
Q1 Define