Learning Advanced Features
194
5.13 Payback Counter
The payback counter displays energy savings information by comparing the average
energy efficiency for operations with and without the inverter. The energy savings
information is displayed as kWh, saved energy cost, and CO2 emission level.
Group
Code
Name
LCD Display
Parameter
Setting
Setting Range
Unit
AP2
87
1
st
MOTOR
average POWER
M1 AVG
PWR
Inverter capacity
0.190.0
kW
88
2
nd
MOTOR
average POWER
M2 AVG
PWR
Inverter capacity
0.190.0
kW
89
Cost per kWh
Cost per
kWh
0
0.01000.0
kW
90
Saved kWh
Saved kWh
0
-999.9999.9
kWh
91
Saved MWh
Saved
MWh
0
-3200032000
MWh
92
Saved Cost below
1000 unit
Saved
Cost1
0
-999.9999.9
-
93
Saved Cost over
1000 unit
Saved
Cost2
0
-3200032000
-
94
Reduced CO2
conversion Factor
CO2 Factor
0.5
0.15.0
-
95
Reduced CO2
(Ton)
Saved CO2
- 1
0
-99999999
Ton
96
Reduced CO2
(1000 Ton)
Saved CO2
- 2
0
-160–160
Ton
97
Reset
Energy payback
parameter
Reset
Energy
0
0
No
-
1
Yes
Energy Payback Value Function Setting Details
Code
Description
AP2-87 M1 AVG PWR
Sets the average power value of the #1 motor and calculates the
energy savings based on the set value.
AP2-88 M2 AVG PWR
Sets the average power of the #2 motor and calculates energy

Table of Contents