Loading...
Learning Advanced Features
254
5.39 User Group
Create a user defined group and register user-selected parameters from the existing
function groups. The user group can carry up to a maximum of 64 parameter registrations.
Group
Code
Name
LCD Display
Parameter Setting
Setting
Range
Unit
CNF
42
Multi-function key settings
Multi Key Sel
3
UserGrp
SelKey
-
-
45
Delete all user registered
codes
UserGrp
AllDel
0
No
-
-
User Group Setting Details
Code
Description
CNF-42 Multi Key
Sel
Select 3 (UserGrp SelKey) from the multi-function key setting options. If
user group parameters are not registered, setting the multi-function key
to the user group select key (UserGrp SelKey) will not display user
group (USR Grp) items on the Keypad.
Follow the procedures below to register parameters to a user group.
No
Procedure
1
Set CNF- 42 to 3 (UserGrp SelKey)‘. A icon will be
displayed at the top of the LCD display.
2
In the parameter mode (PAR Mode), move to the parameter
you need to register and press the [MULTI] key. For example,
if the [MULTI] key is pressed in the frequency reference in
DRV-01 (Cmd Frequency), the screen below will be
displayed.
󰪻 Group name and code number of the parameter
󰪼 Name of the parameter
󰪽 Code number to be used in the user group. Pressing the
[PROG/ENT] key on the code number (40 Code) will register
DRV-01 as code 40 in the user group.

Table of Contents