EasyManua.ls Logo

LSIS LSLV0055H100-4COFN - Digital Output; Multi-Function Output Terminal and Relay Settings

LSIS LSLV0055H100-4COFN
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
305
Learning Advanced Features
5.48 Digital Output
5.48.1 Multi-function Output Terminal and Relay Settings
Group
Code
Name
LCD Display
Parameter
Setting
Setting Range
Unit
OUT
31
Multi-function relay
1 setting
Relay 1
23
Trip
-
-
32
Multi-function relay
2 setting
Relay 2
14
Run
-
-
33
Multi-function relay
3 setting
Relay 3
0
None
-
-
34
Multi-function relay
4 setting
Relay 4
0
None
-
-
35
Multi-function relay
5 setting
Relay 5
0
None
-
-
36
Multi-function
output setting
Q1 define
0
None
-
-
41
Multi-function
output monitor
DO Status
-
0011
bit
57
Detection
frequency
FDT
Frequency
30.00
0.00–Maximum
frequency
Hz
58
Detection
frequency band
FDT Band
10.00
IN
65
71
Px terminal
configuration
Px Define
18
Exchange
0-55
-
Multi-function Output Terminal and Relay Setting Details
Code
Description
OUT-3135
Relay15
Set relay (Relay 1–5) output options.
Setting
Function
0
None
No output signal
1
FDT-1
Detects inverter output frequency reaching the user set
frequency. Outputs a signal when the absolute value
(set frequency–output frequency) < detected frequency