Learning Advanced Features
252
Code
Description
CNF-50 View Lock
Set
To enable parameter view lock, enter a registered password. The
[Locked] sign will be displayed on the screen to indicate that parameter
view lock is enabled. To disable parameter view lock, re-enter the
password. The [locked] sign will disappear.
5.37 Parameter Lock
Use parameter lock to prevent unauthorized modification of parameter settings. To enable
parameter lock, register and enter a user password first.
Group
Code
Name
LCD Display
Parameter
Setting
Setting
Range
Unit
CNF
52
Parameter lock
Key Lock Set
Un-locked
09999
-
53
Parameter lock password
Key Lock Pw
Password
09999
-
Parameter Lock Setting Details
Code
Description
CNF-53 Key Lock
PW
Register a password to prohibit parameter modifications. Follow the
procedures below to register a password.
No
Procedures
1
Press the [PROG/ENT] key on CNF-53 code and the saved
password input window will be displayed. If password registration
is being made for the first time, enter 0‘. It is the factory default.
2
If a saved password has been set, enter the saved password.
3
If the entered password matches the saved password, then a
new window to enter a new password will be displayed. (The
process will not move to next stage until the user enters a valid
password).
4
Register a new password.
5
After registration, Code CNF-53 will be displayed.