359
RS-485 Communication Features
7.3.5 Parameter Group for User/Macro Group
By defining user/macro parameter groups, communication can be carried out using the user
defined group (USR Grp) and macro group (MAC Grp) addresses that are registered at the
U&M mode. Parameter groups can only be defined when using the keypad.
Currently Registered User Group Parameters
Address
Parameter
Assigned Content by Bit
0h0200
User Grp.
Code 1
Parameter value registered at U&M > USR 1 (Read/Write
access)
0h0201
User Grp.
Code 2
Parameter value registered at U&M > USR 2 (Read/Write
access)
.
.
.
.
.
.
.
.
.
0h023E
User Grp.
Code 63
Parameter value registered at U&M > USR 63 (Read/Write
access)
0h023F
User Grp.
Code 64
Parameter value registered at U&M > USR 64 (Read/Write
access)
Currently Registered Macro Group Parameters
Address
Parameter
Assigned Content by Bit
0h0240
Macro Grp. Code 1
Parameter value registered at U&M > MC 1
0h0241
Macro Grp. Code 2
Parameter value registered at U&M > MC 1
.
.
.
.
.
.
.
.
.
0h02A2
Macro Grp. Code 98
Parameter value registered at U&M > MC 98
0h02A3
Macro Grp. Code 99
Parameter value registered at U&M > MC 99