EasyManua.ls Logo

LSIS LSLV0055H100-4COFN - H100 Expansion Common Area Parameter

LSIS LSLV0055H100-4COFN
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS-485 Communication Features
374
Comm.
Address
Address
Parameter
Scale
Unit
R/W
Assigned Content by Bit
0h0016
Motor rotation speed
1
Rpm
R
Displays existing motor rotation
speed
0h0017
0h0019
Reserved
-
-
-
-
0h001A
Select Hz/rpm
-
-
R
0: Hz unit, 1: rpm unit
0h001B
Display the number
of poles for the
selected motor
-
-
R
Display the number of poles for
the selected motor
7.3.9 H100 Expansion Common Area Parameter
7.3.9.1 Monitoring Area Parameter (Read Only)
Comm.
Address
Parameter
Scale
Unit
Assigned content by bit
0h0300
Inverter model
-
-
H100: 000Fh
0h0301
Inverter capacity
-
-
5.5 kW: 4055h, 7.5 kW: 4075h
11 kW: 40B0h, 15 kW: 40F0h
18.5 kW: 4125h, 22 kW: 4160h
30 kW: 41E0h, 37 kW: 4250h,
45 kW: 42D0h,55 kW: 4370h,
75 kW: 44B0h,90 kW: 45A0h,
0h0302
Inverter input
voltage/power (Single
phase, 3-phase)/cooling
method
-
-
200 V 3-phase forced cooling: 0231h
400 V 3-phase forced cooling: 0431h
0h0303
Inverter S/W version
-
-
(ex) 0h0064: Version 1.00
0h0065: Version 1.01
0h0304
Reserved
-
-
-
0h0305
Inverter operation state
-
-
B15
0: Normal state

Table of Contents

Related product manuals