Technical Specification
554
Maximum allowed prospective short-circuit current at the input power connection is defined
in IEC 60439-1 as 100 kA. LSLV-H100 is suitable for use in a circuit capable of delivering
not more than 100kA RMS at the drive‘s maximum rated voltage, depending on the
selected MCCB. RMS symmetrical amperes for recommended MCCB are the following
table.
Working
Voltage
UTE100
(E/N)
UTS150
(N/H/L)
UTS250
(N/H/L)
UTS400
(N/H/L)
240V(50/60Hz)
50/65kA
65/100/150kA
65/100/150kA
65/100/150kA
480V(50/60Hz)
25/35kA
35/65/100kA
35/65/100kA
35/65/100kA
Working
Voltage
ABS33c
ABS53c
ABS63c
ABS103c
ABS20
3c
ABS403c
240V(50/60Hz)
30kA
35kA
35kA
85kA
85kA
75kA
480V(50/60Hz)
7.5kA
10kA
10kA
26kA
26kA
35kA
11.5 Fuse and Reactors Specifications
Products(kW)
AC Input Fuse
AC reactor
DC Reactor
Current
(A)
Voltage
(V)
Inductanc
e
(mH)
Current
(A)
Inductanc
e
(mH)
Current
(A)
3-Phase
200 V
0.75
10
600[V]
2.02
5
4.04
5
1.5
10
1.26
8
2.53
8
2.2
15
0.78
12
1.68
12
3.7
20
0.59
16
1.26
16
5.5
50
0.43
24
0.93
25
7.5
63
0.31
33
0.73
32
11
80
0.22
46
0.53
50
15
100
0.16
62
0.32
62
18.5
125
0.13
77
0.29
80