Maintenance
541
541
10.3 Storage and Disposal
10.3.1 Storage
If you are not using the product for an extended period, store it in the following way:
Store the product in the same environmental conditions as specified for operation
(Refer to 1.3 Installation Considerationson page 5).
When storing the product for a period longer than 3 months, store it between -10 ˚C
and 30 ˚C, to prevent depletion of the electrolytic capacitor.
Do not expose the inverter to snow, rain, fog, or dust.
Package the inverter in a way that prevents contact with moisture. Keep the moisture
level below 70% in the package by including a desiccant, such as silica gel.
Do not allow the inverter to be exposed to dusty or humid environments. If the inverter
is installed in such environments (for example, a construction site) and the inverter will
be unused for an extended period, remove the inverter and store it in a safe place.
10.3.2 Disposal
When disposing of the product, categorize it as general industrial waste. Recyclable
materials are included in the product, so recycle them whenever possible. The packing
materials and all metal parts can be recycled. Although plastic can also be recycled, it can
be incinerated under contolled conditions in some regions.
If the inverter has not been operated for a long time, capacitors lose their charging
characteristics and are depleted. To prevent depletion, turn on the product once a year and allow
the device to operate for 30-60 min. Run the device under no-load conditions.