129
Learning Basic Features
The amount of DC braking required is based on the motor‘s rated current. Do not use DC
braking resistance values that can cause current draw to exceed the rated current of the inverter.
If the DC braking resistance is too high or brake time is too long, the motor may overheat or be
damaged
4.17 Stop Mode Setting
Select a stop mode to stop the inverter operation.
4.17.1 Deceleration Stop
Deceleration stop is a general stop mode. If there are no extra settings applied, the motor
decelerates down to 0 Hz and stops, as shown in the figure below.
Group
Code
Name
LCD Display
Parameter
Setting
Setting
Range
Unit
ADV
08
Stop mode
Stop Mode
0
Dec
0–4
-