EasyManua.ls Logo

LSIS LSLV0055H100-4COFN - Parameter Group for Data Transmission

LSIS LSLV0055H100-4COFN
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS-485 Communication Features
358
Communication Area
Memory Map
Details
0h1E00
M2 Group
7.3.4 Parameter Group for Data Transmission
By defining a parameter group for data transmission, the communication addresses
registered in the communication function group (COM) can be used in communication.
Parameter group for data transmission may be defined to transmit multiple parameters at
once, into the communication frame.
Group
Code
Name
LCD Display
Parameter
Setting
Setting
range
Unit
COM
3138
Output
communication
address x
Para Status-x
-
0000
FFFF
Hex
5158
Input communication
address x
Para Control-
x
-
0000
FFFF
Hex
Currently Registered CM Group Parameter
Address
Parameter
Assigned content by bit
0h01000h0107
Status Parameter-1
Status Parameter-8
Parameter communication code value registered at
COM-3138 (Read-only)
0h01100h0117
Control Parameter-1
Control Parameter-8
Parameter communication code value registered at
COM-5158 (Read/Write access)
Note
When registering control parameters, register the operation speed (0h0005, 0h0380, 0h0381)
and operation command (0h0006, 0h0382) parameters at the end of a parameter control
frame. For example, when the parameter control frame has 5 parameter control items (Para
Control - x), register the operation speed at Para Control-4 and the operation command to
Para Control-5.