Learning Basic Features
84
4.2.1 Keypad as the Source (KeyPad-1 setting)
You can modify frequency reference by using the keypad and apply changes by pressing
the [ENT/PROG] key. To use the keypad as a frequency reference input source, go to DRV-
07 (Frequency refernce source) and change the parameter value to 0 (Keypad-1)‘. Input
the frequency reference for an operation at DRV-01 (Frequency reference).
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
DRV
01
Frequency
reference
Cmd Frequency
0.00
0.00, Low
FreqHigh
Freq*
Hz
07
Frequency
reference
source
Freq Ref Src
0
KeyPad-
1
011
-
* You cannot set a frequency reference that exceeds the Max. Frequency, as configured
with DRV-20.
4.2.2 Keypad as the Source (KeyPad-2 setting)
You can use the [UP] and [DOWN] cursor keys to modify a frequency reference. To use this
as a second option, set the keypad as the source of the frequency reference, by going to
DRV-07 (Frequency reference source) and change the parameter value to1 (Keypad-2)‘.
This allows frequency reference values to be increased or decreased by pressing the [UP]
and [DOWN] cursor keys.
Group
Code
Name
LCD
Display
Parameter Setting
Setting Range
Unit
DRV
07
Frequency
reference
source
Freq Ref
Src
1
KeyPad-
2
011
-
01
Frequency
reference
0.00
0.00, Low Freq
High Freq*
Hz
*You cannot set a frequency reference that exceeds the Max. Frequency, as configured
with DRV-20.
4.2.3 V1 Terminal as the Source
You can set and modify a frequency reference by setting voltage inputs when using the V1
terminal. Use voltage inputs ranging from 010 V (unipolar) for forward only operation. Use