Learning Protection Features
6.2.5 Dynamic Braking (DB) Resistor Configuration
For H100 series, the braking resistor circuit is integrated inside the inverter.
Group
Code
Name
LCD Display
Parameter
Setting
Setting
range
Unit
PRT
66
Braking resistor
configuration
DB Warn %ED
0
030
%
OUT
3135
Multi-function
relay 15 item
Relay 1–5
25
DB
Warn %ED
-
-
36
Multi-function
output 1 item
Q1 Define
Dynamic Breaking Resistor Setting Details
Code
Description
PRT-66 DB
Warn %ED
Set the braking resistor configuration (%ED: Duty cycle). The braking
resistor configuration sets the rate at which the braking resistor operates
for one operation cycle. The maximum time for continuous braking is 15
sec and the braking resistor signal is not output from the inverter after the
15 sec period elapses. An example of braking resistor set up is as follows:


   

[Example 1]


   
