Learning Advanced Features
The following is an example of an inverter operation utilizing the Time Period modules 1 and
2 with Time Events 1 and 2:
Time Period 1 is used to operate the inverter on Mondays and Tuesdays from 10AM to
8PM. Time Period 2 is used to operate the inverter on Tuesday from 12PM to 5PM.
Time Event 1 triggers forward operations based on the frequency input on the keypad and
continues the operation for the time set at Time Period module 1. Time Event 2 operates
the inverter at Speed-L for the time set at Time Period module 2.
On Mondays, the inverter operates in the forward direction based on the frequency input on
the keypad from 10AM to 8PM (Time Event 1). On Tuesdays, it operates again in the
forward direction based on the keypad frequency input from 10AM to 12PM (Time Event 1),
and then operates at Speed-L from 12PM to 5PM (Time Event 2). When the operation
assigned by Time Event 2 is complete, the inverter resumes its Time Event 1 operation (the
inverter operates based on the keypad frequency input from 5PM to 8PM).
<An example of Time Event>
When repetitive frequency commands related to the frequency input command occur while the
Time Event function is performing, Time Event performs its function in the order of the frequency