Learning Protection Features
To operate the motor overheat protection, connect the overheat protection temperature
sensor (PT 100, PTC) installed in the motor to the inverter‘s analog input terminal.
Selecting the operation
after the detection of the
motor overheat
detection sensor
Selecting the input of
the motor overheat
detection sensor
Fault level of the motor
overheat detection
sensor
Fault area of the motor
overheat detection
sensor
Motor Overheat Protect Sensor Input Detail Settings
Sets the inverter operation state when motor is overheated.
Do not operate when motor overheating is detected.
When the motor is overheated, the inverter output is
blocked and the motor will free-run by inertia.
When the motor is over heated, the motor
decelerates and stops.
Selects the type of the terminal when the motor overheat protect sensor is
connected to the volt (V1) or current (I2) input terminal of the terminal
block in the inverter.
Configure the motor overheat protect sensor
connection to terminal block V1.
Configure the motor overheat protect sensor