Learning Protection Features
324
Group
Code
Name
LCD Display
Parameter
Setting
Setting range
Unit
59
Flux Braking Gain
Flux Brake
kp
0
0150
-
OUT
31
35
Multi-function relay
1–5 item
Relay 1–5
9
Stall
-
-
36
Multi-function
output 1 item
Q1 Define
Stall Prevention Function and Flux Braking Setting Details
Code
Description
PRT-50
Stall
Prevent
Stall prevention can be configured for acceleration, deceleration, or while
operating a motor at constant speed.When the LCD segment is on, the
corresponding bit is off.
Item
Bit Status (On)
Bit Status (Off)
Keypad display
Setting
Function
Bit 4
Bit 3
Bit 2
Bit 1
Stall protection during acceleration
Stall protection while operating at a
constant speed
Stall protection during deceleration
Flux braking during deceleration
Setting
Function
0001
Stall protection
during
acceleration
If inverter output current exceeds the preset stall
level (PRT- 52, 54, 56, 58) during acceleration,
the motor stops accelerating and starts
decelerating. If current level stays above the
stall level, the motor decelerates to the start
frequency (DRV-19). If the current level causes
deceleration below the preset level while
operating the stall protection function, the motor
resumes acceleration.
0010
Stall protection
Similar to stall protection function during

Table of Contents