If you want to deactivate MIB late only for several fixtures on the executor, store these fixtures in the
previous cue with a dimmer values of 1.
Cue Zero
To activate cue zero for the executor, tap at the prohibition sign.
If cue zero is on, the dot2 creates a not visible cue zero on this executor.
The cue zero stores the default values of any attributes which are used in any cue on this executor.
If cue zero is on, any attributes which are used in any cue on this executor will have their default values additional to
the values of the current cue.
Example Cue Zero On:
Let´s assume, you have stored fixture 1 thru 3 in blue at executor 1.
In cue 1 of executor 2 is fixture 1 stored in red.
In cue 2 of executor 2 is fixture 2 stored in green.
In cue 3 of executor 2 is fixture 3 stored in green.
Cue zero is on for executor 2.
Start executor 1 gives you three fixtures in blue.
Start cue 1 of executor 2 gives you fixture 1 in red.
Fixture 2 and 3 have their default values because they are used on executor 2 in cue 2 and cue 3.
Example Cue Zero Off:
Same initial situation as in example cue zero on.
Start cue 1 of executor 2 gives you fixture 1 in red.
Fixture 2 and 3 are keeping the values from executor 1.
Example Cue Zero On - Copy with Status:
Let´s assume, you will copy cue 1 at cue 4 as it is and without tracking values from cue 3.
Turn cue zero on and choose copy method with status.Copy cue 1 at cue 4.