10.2 Pre-Installation
1. Prior to installing the actuator unit, check that all uid lines in the mold
plate are deburred and clean.
2. Use denatured alcohol to remove the rust inhibitor compound from each
part. Do not clean the interior of the cylinder.
10.3 Cylinder Bottom Assembly
1. Insert the rod seal support disk into the cylinder (6X00 Series and 7100
Series only).
2. Press the rod seal into position.
3. Install the circlip with sharp edges facing up.
4. Lubricate the bottom cylinder external O-rings and install.
1. Circlip
2. Rod seal
Figure 10-2 6X00 Series and 7100 Series bottom cylinder
Figure 10-3 6X00 Series and 7100 Series bottom cylinder O-rings
1. Back-up ring 2. Inner Viton O-ring 3. Outer seal
1
2
3
Figure 10-4 Seal kit PS0003
1
2
10-2
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.