20.6.12 Parts Sticking to Cavity
The nished product does not properly release from the mold (female side).
Probable Cause:
1. Molding Machine
High injection pressure
High injection speed
Long holding time
High material feed
2. Mold
Hot cavity
Cold mold
Defective mold surface
3. Material
Melt too hot
Solution (in sequence):
1. Conrm cycle time for cooling
2. Reduce injection pressure
3. Reduce injection hold time
4. Reduce injection speed
5. Reduce injection time
6. Adjust feed
7. Inspect mold nish
8. Increase mold opening cycle
9. Lower mold temperature
10. Adjust di󰀨erential temperatures
11. Inspect for appropriate mold release
20-16