20.6.13 Parts Sticking to Core
The nished product does not properly release from the mold (male side).
Probable Cause:
1. Molding Machine
High injection pressure
2. Mold
Hot core
Bending of core
Presence of vacuum
3. Material
Generally not a material related issue
Solution (in sequence):
1. Conrm cycle time for cooling
2. Reduce injection pressure
3. Reduce injection hold time
4. Reduce injection time
5. Adjust feed
6. Reduce mold closed time
7. Increase core temperature
8. Decrease nozzle temperature
9. Inspect mold for undercuts and / or improper draft
10. Verify mold bending ratio
20-17TROUBLESHOOTING