13.3.11 Inspect Parallelism of the Synchro-Plate
CAUTION
Do not run the E-Drive when the synchro-plate is not in the parallel position.
It will damage the part.
CAUTION
1. Use the depth gauge tools and inspect the parallelism with the help of the
measuring holes provided in the system.
Measuring holes
Enlarged view
2. Once the parallelism is conrmed, tighten the screws (2 Nos) in each ball-
screw pulley.
Screws
13.3.12 Assemble the Insulation Plate and Locating Ring