NEC ELECTRA ELITE IPK II - Connectors; LED Indications

NEC ELECTRA ELITE IPK II
642 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
___________________________________________________________________________________
6 - 26 Installing ETUs (Circuit Cards)
___________________________________________________________________________________
Document Revision 3 Electra Elite IPK II
CN301 and CN302
Set the 100 Ω termination to On or Off for Circuit 3. Jumper Pins 1
and 2 are shorted together at the factory to turn on the 1100 Ω
terminal.
CN401 and CN402
Set the 100 Ω termination to On or Off for Circuit 4. Jumper Pins 1
and 2 are shorted together at the factory to turn on the 100 Ω
terminal.
5.2.5 LED Indications
Refer to Table 6-6 BRT(4)-U20 ETU LED Indications.
5.2.6 Connectors
The following connectors are included:
J
CN1 Connects to the backplane.
J
CN3 DB9 Pin Male connector used for maintenance
Table 6-6 BRT(4)-U20 ETU LED Indications
LED Description On Flashing Off
LED 1 ETU status Operation
stopped
(Power On)
Normal
Operation
No
Power
LED 2 L1 status - BRI
CKT1
L1 working Not Used L1 idle
LED 3 L1 status - BRI
CKT2
L1 working Not Used L1 idle
LED 4 L1 status - BRI
CKT3
L1 working Not Used L1 idle
LED 5 L1 status - BRI
CKT4
L1 working Not Used L1 idle
LED 6 B1 or B2 status
Circuit 1
Busy Not Used Idle
LED 7 B1 or B2 status
Circuit 2
Busy Not Used Idle
LED 8 B1 or B2 status
Circuit 3
Busy Not Used Idle
LED 9 B1 or B2 status
Circuit 4
Busy Not Used Idle