9 - 12 Installing Electra Elite IPK II Optional Terminal Equipment
___________________________________________________________________________________
Document Revision 3 Electra Elite IPK II
To provide control to the recorder or to enable/disable the record
start warning tones, refer to Table 9-2 AD(A)-R Unit Switch Settings.
3.2.3 Installing the AD(A)-R Unit on a Multiline Terminal
The AD(A)-R Unit should be installed
after the cables are connected
and the switches are set.
If wall mounting the Multiline Terminal, a WM-R Unit must be used.
Refer to Section 13 Wall Mounting Multiline Terminals on page 8-29.
1. Unplug the telephone cord (and the AC-2R/AC-3R Unit cord if
installed) from the Multiline Terminal.
Table 9-2 AD(A)-R Unit Switch Settings
Switch Description/Settings
SW1
SW1-1 Connects to Multiline Terminal
Connect = Default
SW1-2 Not Used
SW2
SW2-1 Sets External Equipment Impedance to 600 Ω
SW2-2 Used for Complex Impedance Devices
(< 30 Ω Input Impedance)
Dip
Switche
s
(DSW)
DSW 1
Output Hook Signal to External Device
On = Output
Off = No Output (Default)
DSW 2
Record Confirmation Tone
On = Tone On
Off = Tone Off (Default)
DSW 3
and
DSW 4
Use T1/T2
On = Disable (Default)
Off = Enable
DSW 5
Reset Signal Upgrade
On = Normal (Default)
Off = Debugging
DSW
6~8
Firmware Upgrade
On = Firmware Upgrade
Off = Disable (Default)
Do not connect T1 and T2 when DSW switches 3 and 4 are On.