3.2 ADA-U Unit (Ancillary Device Adapter)
Ancillary Device Adapters allow connection of a tape recorder to all DTU/DTP
Multiline Terminals except DTP-2DT-1 and DTP-16HC-1.
When installing an ADA-U Unit, first connect the cables to the ADA-U Unit, set
the dip switches, and then install the ADA-U Unit on the Multiline Terminal.
3.2.1 Installing an ADA-U Unit on a Multiline Terminal
1. Unplug the telephone cord from the Multiline Terminal.
2. Prepare Multiline Terminal for adapter installation. Refer to
Section 2 Preparing Multiline Terminal for Adapter Installation.
3. Plug the ADA-U Unit connector into the receptacle connector
on the back of the Multiline Terminal. Snap the ADA-U Unit into
the hooks on the Multiline Terminal to secure it.
Figure 11-9 ACA-U Unit Connection
AC Adapter Plug