Electra Elite IPK II Document Revision 3
System Hardware Manual 6 - 85
___________________________________________________________________________________
___________________________________________________________________________________
6.8.4 LED Indications
LED 1 (LIVE) indications are:
J
Flashing Red Normal Operation
J
Steady Red Operation Stopped (Power On).
J
Off No Power
LED 2 (BUSY) indications are:
J
Steady Red Some ports busy
J
Off All ports idle
Table 6-27 SW2-2/SW2-3 Details
SW 2-2 SW 2-3 Function
ON ON
Factory Test
OFF
ON
Firmware Upgrade
ON
OFF Not Used
OFF OFF
Normal Operation
(Default)
Table 6-28 SLIB(4)-U10 ETU SW3 Switch Settings
SW 3-1 SW 3-2 SW 3-3 SW 3-4 Country Selection
ON ON ON ON
North America (Default)
ON OFF OFF ON
Multiple SLT Devices (One
Single Line Telephone and
one External Loud Ringer)
Firmware Version 1.72 or higher is required for the Multiple SLT
Devices setting.