7.1.4 LED Indications
Refer to Table 6-31 CMS(2)/(4)-U( ) ETU LED Indicators.
Table 6-31 CMS(2)/(4)-U( ) ETU LED Indicators
LED Description On Flashing Off
LIVE ETU status Receiving
Power
Not Used No Power
CH1 Port Status Busy Not Used Idle/Not
Used
CH2 Port Status Busy Not Used Idle/Not
Used
CH3 Port Status Busy Not Used Idle/Not
Used
CH4 Port Status Busy Not Used Idle/Not
Used
MB MB Switch Status ON Not Used OFF
BIOS DOS Status BIOS Error Not Used No error
BCLR Application Status Red: DOS
started
(VM Not
Ready)
Green: VM
Running
Orange: Error
Not Used Idle
If BCLR LED is orange, check error type on console screen.
After error is corrected, LED automatically changes to green.
Do Not connect link between console and ETU until BCLR turns
green during booting.
HD Flash Status Not Used Compact
Flash Disk
Active
Flash
Inactive