3 - 28 System Specifications
___________________________________________________________________________________
Document Revision 3 Electra Elite IPK II
Maximum Current: 250 mA
Acoustical characteristics meet Electronic Industry Association
(EIA) standard proposal SP-1286 and standard EIA RS-470.
J
Single Line Telephone
Standard 2500 Set: 500 type network
Nominal Current: 35 mA
Ring Signal: 56 Vac RMS @ 20 Hz
J
SLT(1)-U( ) ADP
Standard 2500 Set: 500 type network
Nominal Current: 30 mA
Ring Signal: 56 Vac RMS @ 20 Hz
J
AP(A)-R Unit
Standard 2500 Set: 500 type network
Nominal Current: 30 mA
J
AP(R)-R Unit
Standard 2500 Set: 500 type network
Nominal Current: 30 mA
Ring Signal: 56 Vac RMS @ 20 Hz
5.5.5 Series i Terminals
The voltage and current information for the D
term
Series i Multiline
Terminals are listed below:
J
Multiline Terminal (Series i)
Voltage: -11 ~ -48 Vdc
Maximum Current: 250 mA
Acoustical characteristics meet Electronic Industry Association
(EIA) standard proposal SP-1286 and standard EIA RS-470.
J
Voltage, current, and ring signal information for Single Line
Telephone equipment, AP(A)-R Unit, and AP(R)-R Unit are the
same as those listed in the previous paragraph.