6 - 132 Installing ETUs (Circuit Cards)
___________________________________________________________________________________
Document Revision 3 Electra Elite IPK II
7.5.6 Switch Settings
Table 6-42 VMP( )-U40 ETU Switch Settings
Reset Power Switch SW1 Used for development only
DIP Switch SW2
1234 Description
ON
Enable HostKey and run Manufacturing Test (NEC
Production use only.
ON ON
Enable HostKey with floppy disk redirection and run
Manufacturing Test (NEC Production use only).
ON
Connect to Cosession using modem instead of direct
cable.
ON Start BRU host with direct cable connection
ON ON Start BRU host with modem connection
ON ON
Connect to Cosession using direct cable connection,
but do not start voice mail software (for
troubleshooting and maintenance only).
Switch SW3 Positions Used to identify ETU operation
RUN LED 6 is on red.
SHUT DOWN LED 7 is on red.