5.2.2 Environmental Conditions
Temperature
J
Operating: +32°F ~ +104°F (0°C ~ 40°C)
J
Long Term: +50°F ~ +90°F (10°C ~ 32.2°C)
Humidity
J
Operating: 10% ~ 90% noncondensing
5.3 Power Requirements
5.3.1 Power Supply Inputs
AC input requirements for the system are listed below.
AC Input [P64-U( ) PSU]
J
117 Vac ± 10%
J
60 Hz ± 10%
J
Single Phase
J
7.5A circuit
J
A dedicated outlet, separately fused and grounded
5.3.2 Power Supply Consumption
The power consumption for the Electra Elite IPK II system is listed in
Table 3-10 Power Consumption.
When replacing fuses, refer to the specifications in Table 3-11 Fuse
Replacement.
Table 3-10 Power Consumption
KSU
Maximum
RMS
Current
Watts
Used
(Idle)
Watts
Used
(Maximum)
Basic KSU – B64-U20 KSU 2.5 A 120 230
Basic KSU + Expansion KSU 5.0 A 240 460
Basic KSU + 2 Expansion KSUs 7.5 A 360 690