Electra Elite IPK II Document Revision 3
System Hardware Manual 6 - 139
___________________________________________________________________________________
___________________________________________________________________________________
Table 6-48 VMS(2)/(4)/(8)-U( ) ETU DIP Switch Functions
DIP
1
DIP
2
DIP
3
DIP
4
Description
ON To enable HostKey and run Manufacturing
Test (NEC Production only).
ON ON To enable HostKey with floppy disk redirection
and run Manufacturing Test (NEC Production
only).
ON To connect to CoSession using modem
instead of direct cable connection.
ON To start BRU Host with direct cable
connection.
ON ON To start BRU Host with modem connection.
ON ON To connect to CoSession using direct cable
connection but not start voice mail software
(Troubleshooting or Maintenance Mode).
Used for Revision Q00631 v 6.68 or higher.