Electra Elite IPK II Document Revision 3
System Hardware Manual 6 - 179
___________________________________________________________________________________
___________________________________________________________________________________
The Boot sequence in this table occurs when the IP Application is
loaded.
The PVA(X)-U( ) should be removed only after the ETU has
completed booting, and LEDs 1~3 on the back of the ETU are ON.
Table 6-71 Default Boot Sequence: In Active PVA(X)-U( ) ETU without IP Application Loaded
State
DS8
CH1
DS7
CH2
DS6
CH3
DS5
CH4
DS4
CH5
DS3
CH6
DS2
CH7
DS1
CH8
DS9
Live
DS10
CF
Busy
LED
3
LED
2
LED
1
Approximate
Time
1 ON ON ON ON ON ON ON ON Flash OFF OFF OFF ON CH1~CH8
Simultaneous
2 ONONONONONONONONFlash OFF OFFOFFONCH1~CH8
Incremental
3 OFF OFF OFF OFF OFF OFF OFF OFF Flash Slow
Blink
OFF OFF ON 1~3 Minutes
4 OFF OFF OFF OFF OFF OFF OFF OFF Flash Flash OFF OFF ON 1~5 Seconds
5 OFF OFF OFF OFF OFF OFF OFF OFF Flash Slow
Blink
OFF OFF ON 1~3 Minutes
6 OFF OFF OFF OFF OFF OFF OFF OFF Flash Fast
Blink
OFF OFF ON 1~3 Minutes
7 OFF OFF OFF OFF OFF OFF OFF OFF Flash OFF OFF OFF ON ACTIVE
Table 6-72 Active PVA(X)-U( ) ETU with IP Application Loaded
State
DS8
CH1
DS7
CH2
DS6
CH3
DS5
CH4
DS4
CH5
DS3
CH6
DS2
CH7
DS1
CH8
DS9
Live
DS10
CF
Busy
LED
3
LED
2
LED
1
Approximate
Time
1 ON ON ON ON ON ON ON ON Flash OFF OFF OFF ON CH1~CH8
Simultaneous
2 ONONONONONONONONFlash OFF OFFOFFONCH1~CH8
Incremental
3 OFF OFF OFF OFF OFF OFF OFF OFF Flash Flash OFF OFF ON 1~3 Minutes
4 OFF OFF OFF OFF OFF OFF OFF OFF Flash OFF OFF OFF ON 1~5 Seconds
5 ONONONONONONONOFFFlash OFF ONOFFONCH1~CH7
Incremental
6 OFF OFF OFF OFF OFF OFF OFF OFF Flash OFF ON ON ON ACTIVE