High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
3
• Do not come close to the machine when using the Restart Selection function (b001, b008) because
the machine may abruptly start when stopped by an alarm.
• Be sure to confirm the RUN signal has turned OFF before resetting the alarm because the machine
may abruptly start.
• Do not come close to the machine when selecting reset in the Deceleration Stop Function (b050)
because the machine may abruptly start after the power is turned on.
• Provide a separate emergency stop switch because the STOP Key on the Operator is valid only when
function settings are performed.
• When checking a signal during the power supply and the voltage is erroneously applied to the control
input terminals, the motor may start abruptly. Be sure to confirm safety before checking a signal.
Precautions for Correct Use
Restart Selection Function
Deceleration Stop Function
Operation Stop Command