7 - 149
7 Detailed Functions
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
7-8 User Setting Display Functions (Group U)
7
7-8 User Setting Display Functions
(Group U)
This section describes the user setting display functions.
In the User Selection 1 to 12 (U001 to U012), register up to 12 user parameters you want to display.
When registration is done, set the Display Selection to 02 (User setting). After that, you will see only the
functions registered with U001 to U012, in addition to d001, F001, and b037.
User Parameter Setting Functions
Parameter No. Function name Data Default data Unit
U001 to U012 User Selection 1 to 12
no: No registration
d001 to P196: Register the parameter
numbers you want to
display
no
b037 Display Selection 02: User setting 00