10 Troubleshooting
10 - 14
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
10-3 Other Indications on Digital Operator
Name Description
Indication on
Digital Operator
During reset
This indication appears when the input terminal allocated to
the reset (RS) function is ON, or when a trip state is reset via
the STOP/RESET key.
Motor rotating
Undervoltage standby
This indication appears when the inverter is in an undervoltage
standby state, or when the power supply is shut off.
Restart during
momentary power
interruption/Restart on
trip
This indication appears while restart operation is in progress.
RUN command limited
This indication appears when the RUN command is input from
the control terminal, with the RUN direction limited by the RUN
Direction Limit Selection (b035) setting.
Setting initialization
This indication appears while the parameter settings are
initialized.
Fault Monitor
initialization
This indication appears while the fault monitor data is
initialized.
No data
This indication appears when there is no applicable data. This
indicates that the fault monitor has no trip data.
Communications error
This indication appears if an error occurs between a remote
Digital Operator and the inverter.
Blinking
Auto-tuning
OK
This indication appears when auto-tuning is completed
normally.
Auto-tuning
NG
This indication appears when auto-tuning is failed.