7 Detailed Functions
7 - 2
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
7-1 Monitor Mode (Group d)
This section describes the output frequency, trip monitor, and other monitor function of the inverter.
Use this function to display the output frequency of the inverter. The value is 0.00 when the inverter is
stopped.
The data display LED “Hz” is lit while the value of d001 is displayed.
• If the Digital Operator is used to set output reference, only during operation, you can change
the Output Frequency Setting/Monitor (F001) setting by entering new data in the Output
Frequency Monitor (After Conversion) (d007) using the Increment/Decrement key.
• The new Output Frequency Monitor (d001) value is reflected on the Output Frequency
Setting/Monitor (F001) setting and stored to the EEPROM when you press the Enter key.
Use this function to display the output current value of the inverter. The value is 0.0 when the inverter is
stopped.
The data display LED “A” is lit while the value of d002 is displayed.
Use this function to display the RUN direction of the inverter.
The RUN LED is lit during inverter operation (in the forward/reverse direction).
Output Frequency Monitor [d001]
Parameter No. Function name Data Default data Unit
d001 Output Frequency Monitor
0.00 to 99.99 (Displayed in increments of
0.01 Hz)
100.0 to 400.0 (Displayed in increments
of 0.1 Hz)
–Hz
Output Current Monitor [d002]
Parameter No. Function name Data Default data Unit
d002 Output Current Monitor
0.0 to 999.9 (Displayed in increments of
0.1A)
1000. to 9999. (Displayed in increments
of 1A)
–A
RUN Direction Monitor [d003]
Parameter No. Function name Data Default data Unit
d003 RUN Direction Monitor
F: Forward
o: Stop
r: Reverse
––