4 Parameter List
4 - 20
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10
b012 1st Electronic
Thermal Level
0.20 x Rated current to 1.00 x
Rated current
Rated
current
value
Disabled Enabled A 7-66
b212 2nd Electronic
Thermal Level
b312 3rd Electronic
Thermal Level
b013 1st Electronic
Thermal
Characteristics
Selection
00: Reduced torque
characteristics
01: Constant torque
characteristics
02: Free setting
00 Disabled Enabled
b213 2nd Electronic
Thermal
Characteristics
Selection
b313 3rd Electronic
Thermal
Characteristics
Selection
b015 Free-electronic
Thermal
Frequency 1
0: Disabled
0. to Free-electronic Thermal
Frequency 2
0. Disabled Enabled Hz
b016 Free-electronic
Thermal Current 1
0.00 to Rated current 0.00 Disabled Enabled A
b017 Free-electronic
Thermal
Frequency 2
0: Disabled
Free-electronic Thermal
Frequency 1 to Free-electronic
Thermal Frequency 3
0. Disabled Enabled Hz
b018 Free-electronic
Thermal Current 2
0.00 to Rated current 0.00 Disabled Enabled A
b019 Free-electronic
Thermal
Frequency 3
0: Disabled
Free-electronic Thermal
Frequency 2. to 400.
0. Disabled Enabled Hz
b020 Free-electronic
Thermal Current 3
0.00 to Rated current 0.00 Disabled Enabled A
Electronic thermal