4 Parameter List
4 - 34
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10
C044 PID Deviation
Excessive Level
0.0 to 100.0 3.0 Disabled Enabled % 7-45
C045 Arrival Frequency
During
Acceleration 2
0.00 to 99.99
100.0 to 400.0
0.00 Disabled Enabled Hz 7-127
C046 Arrival Frequency
During
Deceleration 2
0.00 to 99.99
100.0 to 400.0
0.00 Disabled Enabled Hz
C052 Feedback
Comparison
Signal Off Level
0.0 to 100.0 100.0 Disabled Enabled % 7-45
C053 Feedback
Comparison
Signal On Level
0.0 to 100.0 0.0 Disabled Enabled %
C055 Overtorque level
(Forward Power
Running)
Heavy
load
(CT)
0. to 200.
(0.4 to 55 kW)
100. Disabled Enabled % 7-129
0. to 180.
(75 to 132 kW)
100.
Light
load
(VT)
0. to 150. 100. Disabled Enabled %
C056 Overtorque level
(Reverse
Regeneration)
Heavy
load
(CT)
0. to 200.
(0.4 to 55 kW)
100. Disabled Enabled %
0. to 180.
(75 to 132 kW)
100.
Light
load
(VT)
0. to 150. 100. Disabled Enabled %
C057 Overtorque level
(Reverse Power
Running)
Heavy
load
(CT)
0. to 200.
(0.4 to 55 kW)
100. Disabled Enabled %
0. to 180.
(75 to 132 kW)
100.
Light
load
(VT)
0. to 150. 100. Disabled Enabled %
C058 Overtorque level
(Forward
Regeneration)
Heavy
load
(CT)
0. to 200.
(0.4 to 55 kW)
100. Disabled Enabled %
0. to 180.
(75 to 132 kW)
100.
Light
load
(VT)
0. to 150. 100. Disabled Enabled %
C061 Electronic
Thermal Warning
Level
0. to 100. 80. Disabled Enabled % 7-71
C062 Alarm Code
Selection
00: Disabled
01: 3 bits
02: 4 bits
00 Disabled Enabled – 7-130
C063 0 Hz Detection
Level
0.00 to 99.99
100.0
0.00 Disabled Enabled Hz 7-130
C064 Cooling Fin
Overheat Warning
Level
0. to 200. 120. Disabled Enabled °C 7-135