4 - 45
4 Parameter List
High-function General-purpose Inverter 3G3RX-V1 User’s Manual (I578-E1)
4-3 Extended Function Mode
4
4-3-5 Group P: Option Parameters
*1 The default data was changed from the previous model.
P070 Origin Search
Mode 1
Frequency
0.00 to 10.00
5.00
*1
Enabled Enabled Hz 6-40
P071 Origin Search
Mode 2
Frequency
0.00 to 99.99
100.0 to 1st Maximum Frequency
(A004)
5.00
*1
Enabled Enabled Hz
P072 Position Limit
Setting (Forward
Side)
0 to 268435455 (When P012 = 02)
0 to 1073741823 (When P012 =
03)
(Displays MSB 4 digits)
268435355 Enabled Enabled –
P073 Position Limit
Setting (Reverse
Side)
–268435455 to 0 (When P012 =
02)
–1073741823 to 0 (When P012 =
03)
Displays MSB 4 digits (1 digit for
“–”)
–268435455
Enabled Enabled –
P074 Teaching
Selection
00: Multi-step Position Command
0 (P060)
01: Multi-step Position Command
1 (P061)
02: Multi-step Position Command
2 (P062)
03: Multi-step Position Command
3 (P063)
04: Multi-step Position Command
4 (P064)
05: Multi-step Position Command
5 (P065)
06: Multi-step Position Command
6 (P066)
07: Multi-step Position Command
7 (P067)
00 Enabled Enabled –
P100
DriveProgramming
User Parameter
U00
0. to 9999.
1000 to 65535
(10000 to 65535)
0. Enabled Enabled – 7-148
P101
DriveProgramming
User Parameter
U01
0. to 9999.
1000 to 65535
(10000 to 65535)
0. Enabled Enabled –
P102
DriveProgramming
User Parameter
U02
0. to 9999.
1000 to 65535
(10000 to 65535)
0. Enabled Enabled –
P103
DriveProgramming
User Parameter
U03
0. to 9999.
1000 to 65535
(10000 to 65535)
0. Enabled Enabled –
P104
DriveProgramming
User Parameter
U04
0. to 9999.
1000 to 65535
(10000 to 65535)
0. Enabled Enabled –
P105
DriveProgramming
User Parameter
U05
0. to 9999.
1000 to 65535
(10000 to 65535)
0. Enabled Enabled –
Parameter
No.
Function name Monitor or data range
Default
data
Changes during
operation
Unit Page
Normal
b031 = 10